ELPH SELFEN CARRIER DEN RANGE: Difference between revisions

From VASP Wiki
No edit summary
No edit summary
Line 2: Line 2:
{{TAGDEF|ELPH_SELFEN_CARRIER_DEN_RANGE|[real array]}}
{{TAGDEF|ELPH_SELFEN_CARRIER_DEN_RANGE|[real array]}}


Description: List of the range of carrier density (in <math>cm^{-3}</math>) at which to compute the phonon-mediated electron self-energy and transport coefficients.  
Description: List of the range of logathrimthic carrier density (in <math>cm^{-3}</math>) at which to compute the phonon-mediated electron self-energy and transport coefficients.  
<!--{{Available|6.5.2}}-->
<!--{{Available|6.5.2}}-->
{{not released}}
{{not released}}

Revision as of 14:41, 17 October 2025

ELPH_SELFEN_CARRIER_DEN_RANGE = [real array] 

Description: List of the range of logathrimthic carrier density (in [math]\displaystyle{ cm^{-3} }[/math]) at which to compute the phonon-mediated electron self-energy and transport coefficients.

   Warning: Not yet released!

This page contains information about a feature that will be available in a future release of VASP. In other words, currently you cannot use it even with the latest version of VASP. The information may change significantly until it is released.


From each carrier density specified in the array, a positive (electron doping) or negative (hole doping) number of electrons is added to the value of NELECT and the chemical potential computed. A range of carrier densities can be defined using ELPH_SELFEN_CARRIER_DEN_RANGE = l u n, where:

  • l is the lower limit of the carrier density range.
  • u is the upper limit of the carrier density range.
  • n is the number of steps between the two limits.

The range of carrier densities is used to generate a log-scale mesh of carrier densities.

Important: When l or u must both be positive (electrons are added, i.e., n-doping) or negative (electrons are removed from - holes are added to - the system, i.e., p-doping).

You can add the range (l u n) N times, so you can have several different meshes of holes or electrons or both. For example, ELPH_SELFEN_CARRIER_DEN_RANGE = -1e20 -1e16 51 1e20 1e16 51 would create a list of two meshes of carrier densities, (-1e20 -1e16 51) and (1e20 1e16 51). The first mesh has 51 carrier densities of holes between -1e16 and -1e20; the second mesh has 51 carrier densities of electrons between 1e16 and 1e20. You could also include more meshes if you want. You can check the carriers that you have chosen in the OUTCAR file:

Chemical potential calculation:
===============================

elph_ismear=-24
elph_fermi_nedos=     501
elph_selfen_carrier_den=
 -0.100E+21
 -0.832E+20
 -0.692E+20
...
 -0.145E+17
 -0.120E+17
 -0.100E+17
  0.100E+21
  0.832E+20
  0.692E+20
...
  0.145E+17
  0.120E+17
  0.100E+17

Related tags and articles