Constrained MD using a canonical ensemble: Difference between revisions

From VASP Wiki
(Created page with "== Download == [http://www.vasp.at/vasp-workshop/examples/h2o_on_tio2.tgz h2o_on_tio2.tgz, sub-folder constrMD_canonical] ---- VASP_example_calculations|To the list of exam...")
 
No edit summary
 
(7 intermediate revisions by one other user not shown)
Line 1: Line 1:
<b>Description</b>:
Compare adsoption  of H2O on TiO2[110] using a simple model structure: the model surface consists of 2 layers TiO2, (1x1)
* The bottom layer of the slab will be kept frozen
* 2 setups will be tested:
** Standard relaxation, minimizing the Hellmann-Feyman forces
** Constrained MD, fixing the bond lengths and angle of H2O, the system is coupled to an ANDERSEN thermostat:
***Microcanonical NVE ensemble (no collisions with the thermostat)
***Canonical ensembe at T= 10K, to be close to the standard relaxation (0K)
 
To keep the computing time reasonable, the number of steps in the MD is limited to 100 (100 fs) which implies that the MD is NOT CONVERGED.
*{{TAG|INCAR}} for standard relaxation
{{TAGBL|SYSTEM}} = H2O_TiO2
{{TAGBL|ENMAX}} = 400
{{TAGBL|ISMEAR}} =  2
{{TAGBL|SIGMA}} = 0.05
{{TAGBL|EDIFF}} = 1e-6
{{TAGBL|EDIFFG}} = -0.05
{{TAGBL|IBRION}} = 2
{{TAGBL|POTIM}} = 0.5
{{TAGBL|NSW}} = 200
*{{TAG|INCAR}} for constrained MD using a microcanonical ensemble
{{TAGBL|SYSTEM}} = H2O_TiO2
{{TAGBL|ENMAX}} = 400
{{TAGBL|ISMEAR}} = 2
{{TAGBL|SIGMA}} = 0.05
{{TAGBL|ISMEAR}} = 0
{{TAGBL|EDIFF}} = 1e-6
{{TAGBL|EDIFFG}} = -0.05
{{TAGBL|IBRION}} = 0
{{TAGBL|POTIM}} = 1.
{{TAGBL|MDALGO}} = 1    # Andersen Thermostat
{{TAGBL|TEBEG}} = 10; {{TAGBL|TEEND}} = 10
{{TAGBL|NSW}} = 100   
*{{TAG|ICONST}} for constrained MD using a microcanonical ensemble
R 7 8 0
R 7 9 0
A 8 7 9 0
*{{TAG|INCAR}} for constrained MD using a canonical ensemble
{{TAGBL|SYSTEM}} = H2O_TiO2
{{TAGBL|ENMAX}} = 400
{{TAGBL|ISMEAR}} = 2
{{TAGBL|SIGMA}} = 0.05
{{TAGBL|ISMEAR}} = 0
{{TAGBL|EDIFF}} = 1e-6
{{TAGBL|EDIFFG}} = -0.05
{{TAGBL|IBRION}} = 0
{{TAGBL|POTIM}} = 1.
{{TAGBL|MDALGO}} = 1    # Andersen Thermostat
{{TAGBL|ANDERSEN_PROB}} = 0.9
{{TAGBL|TEBEG}} = 10; {{TAGBL|TEEND}} = 10
{{TAGBL|NSW}} = 100
*{{TAG|ICONST}} for constrained MD using a canonical ensemble
R 7 8 0
R 7 9 0
A 8 7 9 0
*{{TAG|POSCAR}}
TiO2+H2O                                   
    1.00000000000000   
      4.61949  0.00000    0.00000
      0.00000  4.61949    0.00000
      0.00000  0.00000  14.7788
    Ti  O  H
      2    5    2
Selective
Direct
  0.00000  0.00000  0.00000    F F F
  0.50000  0.50000  0.10000    T T T
  0.30374  0.30374  0.00000    F F F
  0.69625  0.69625  0.00000    F F F
  0.19625  0.80374  0.10000    T T T
  0.80374  0.19625  0.10000    T T T
  0.50000  0.50000  0.31500    T T T
  0.37720  0.62280  0.35881    T T T
  0.62280  0.37720  0.35881    T T T
*{{TAG|KPOINTS}}
Automatically generated mesh
        0
Gamma
  5 5 1
== Download ==
== Download ==
[http://www.vasp.at/vasp-workshop/examples/h2o_on_tio2.tgz h2o_on_tio2.tgz, sub-folder constrMD_canonical]
[http://www.vasp.at/vasp-workshop/examples/h2o_on_tio2.tgz h2o_on_tio2.tgz, sub-folder constrMD_canonical]
----
----
[[VASP_example_calculations|To the list of examples]] or to the [[The_VASP_Manual|main page]]
[[VASP_example_calculations|To the list of examples]] or to the [[The_VASP_Manual|main page]]


[[Category:Examples]]
<!-- [[Category:Examples]] -->

Latest revision as of 18:10, 23 June 2019

Description: Compare adsoption of H2O on TiO2[110] using a simple model structure: the model surface consists of 2 layers TiO2, (1x1)

  • The bottom layer of the slab will be kept frozen
  • 2 setups will be tested:
    • Standard relaxation, minimizing the Hellmann-Feyman forces
    • Constrained MD, fixing the bond lengths and angle of H2O, the system is coupled to an ANDERSEN thermostat:
      • Microcanonical NVE ensemble (no collisions with the thermostat)
      • Canonical ensembe at T= 10K, to be close to the standard relaxation (0K)

To keep the computing time reasonable, the number of steps in the MD is limited to 100 (100 fs) which implies that the MD is NOT CONVERGED.

  • INCAR for standard relaxation
SYSTEM = H2O_TiO2
ENMAX = 400
ISMEAR =  2
SIGMA = 0.05
EDIFF = 1e-6
EDIFFG = -0.05
IBRION = 2
POTIM = 0.5
NSW = 200


  • INCAR for constrained MD using a microcanonical ensemble
SYSTEM = H2O_TiO2
ENMAX = 400
ISMEAR = 2
SIGMA = 0.05
ISMEAR = 0
EDIFF = 1e-6
EDIFFG = -0.05
IBRION = 0
POTIM = 1.
MDALGO = 1    # Andersen Thermostat
TEBEG = 10; TEEND = 10
NSW = 100    
  • ICONST for constrained MD using a microcanonical ensemble
R 7 8 0
R 7 9 0
A 8 7 9 0


  • INCAR for constrained MD using a canonical ensemble
SYSTEM = H2O_TiO2
ENMAX = 400
ISMEAR = 2
SIGMA = 0.05
ISMEAR = 0
EDIFF = 1e-6
EDIFFG = -0.05
IBRION = 0
POTIM = 1.
MDALGO = 1    # Andersen Thermostat
ANDERSEN_PROB = 0.9
TEBEG = 10; TEEND = 10
NSW = 100
  • ICONST for constrained MD using a canonical ensemble
R 7 8 0
R 7 9 0
A 8 7 9 0


TiO2+H2O                                    
   1.00000000000000     
     4.61949   0.00000    0.00000
     0.00000   4.61949    0.00000
     0.00000   0.00000   14.7788
   Ti   O  H
     2     5     2
Selective
Direct
  0.00000  0.00000  0.00000    F F F
  0.50000  0.50000  0.10000    T T T
  0.30374  0.30374  0.00000    F F F
  0.69625  0.69625  0.00000    F F F
  0.19625  0.80374  0.10000    T T T
  0.80374  0.19625  0.10000    T T T
  0.50000  0.50000  0.31500    T T T
  0.37720  0.62280  0.35881    T T T
  0.62280  0.37720  0.35881    T T T


Automatically generated mesh
       0
Gamma
 5 5 1

Download

h2o_on_tio2.tgz, sub-folder constrMD_canonical


To the list of examples or to the main page