Requests for technical support from the VASP group should be posted in the VASP-forum.

Difference between revisions of "ML CTIFOR"

From Vaspwiki
Jump to navigationJump to search
Line 13: Line 13:
 
----
 
----
  
[[Category:INCAR]][[Category:Machine Learning]][[Category:Machine Learned Force Fields]]
+
[[Category:INCAR]][[Category:Machine Learning]][[Category:Machine Learned Force Fields]][[Category: Alpha]]

Revision as of 15:15, 29 February 2020

ML_FF_CTIFOR = [real]
Default: ML_FF_CTIFOR =  

Description: This flag sets the threshold for the Bayesian error estimation on the force in the machine learning force field method.


Within the learning step if a newly considered structure gives an error in the force larger than ML_FF_CTIFOR, the sampling is stopped and a new force field is generated. This flag is only used if ML_FF_IERR=2 or 3. The unit of ML_FF_CTIFOR is eV/Angstrom.

Related Tags and Sections

ML_FF_LMLFF, ML_FF_IERR, ML_FF_CSF

[[Special:Search/"ML_FF_C TIFOR" incategory:"Examples"|Examples that use this tag]]