NELM = [integer]
Default: NELM = 60 

Description: NELM sets the maximum number of electronic SC (selfconsistency) steps which may be performed.


Normally, there is no need to change the default value: if the self-consistency loop does not converge within 40 steps, it will probably not converge at all. In this case you should reconsider the tags IALGO or ALGO, LSUBROT, and the mixing-parameters.

Related Tags and Sections

NELMDL, NELMIN

Examples that use this tag