Jump to content

Requests for technical support from the VASP team should be posted in the VASP Forum.

LTHOMAS: Difference between revisions

From VASP Wiki
Ftran (talk | contribs)
No edit summary
Ftran (talk | contribs)
No edit summary
Line 11: Line 11:
*If {{TAG|LTHOMAS}}{{=}}.TRUE., then {{TAG|LHFCALC}}{{=}}.TRUE. is automatically set.
*If {{TAG|LTHOMAS}}{{=}}.TRUE., then {{TAG|LHFCALC}}{{=}}.TRUE. is automatically set.
*If {{TAG|LTHOMAS}}{{=}}.TRUE., then {{TAG|AEXX}}{{=}}1 is automatically set, but {{TAG|AEXX}} can be set to another value.}}
*If {{TAG|LTHOMAS}}{{=}}.TRUE., then {{TAG|AEXX}}{{=}}1 is automatically set, but {{TAG|AEXX}} can be set to another value.}}
{{NB|important|When {{TAG|AEXX}}{{=}}1 (the default for {{TAG|LTHOMAS}}{{=}}.TRUE.), the correlation <math>E_{\mathrm{c}}^{\mathrm{SL}}</math> is not included. However, it can be included by setting {{TAG|ALDAC}}{{=}}1.0 and {{TAG|AGGAC}}{{=}}1.0.}}
Since VASP counts the semi-core states and ''d''-states as valence electrons, although these states do not contribute to the screening, the values reported by VASP are often not recommended.
Since VASP counts the semi-core states and ''d''-states as valence electrons, although these states do not contribute to the screening, the values reported by VASP are often not recommended.



Revision as of 09:37, 21 October 2025

LTHOMAS = .TRUE. | .FALSE.
Default: LTHOMAS = .FALSE. 

Description: LTHOMAS selects a decomposition of the exchange functional based on Thomas-Fermi exponential screening.


If LTHOMAS=.TRUE. the decomposition of the exchange operator (in a range-separated hybrid functional) into a short range and a long range part will be based on Thomas-Fermi exponential screening. The Thomas-Fermi screening length kTF is specified by means of the HFSCREEN tag.

For typical semiconductors, a Thomas-Fermi screening length kTF of about 1.8 Å-1 yields reasonable band gaps. In principle, however, the Thomas-Fermi screening length depends on the valence-electron density. VASP determines kTF from the number of valence electrons (read from the POTCAR file) and the volume (average density n¯) and writes the corresponding value of kTF=4kF/π, where kF=(3π2n¯)1/3 to the OUTCAR file (note that this value is only printed for information; it is not used during the calculation):

 Thomas-Fermi vector in A             =   2.00000

Since VASP counts the semi-core states and d-states as valence electrons, although these states do not contribute to the screening, the values reported by VASP are often not recommended.