Constrained molecular dynamics: Difference between revisions

From VASP Wiki
(Created page with "<div id="SHAKE"></div> Constrained molecular dynamics is performed using the SHAKE algorithm.<ref name="Ryckaert77"/>. In this algorithm, the Lagrangian for the system <math>\...")
 
No edit summary
 
(20 intermediate revisions by 3 users not shown)
Line 34: Line 34:


<div id="Slowgro"></div>
<div id="Slowgro"></div>
== How to ==
Geometric constraints are introduced by defining one or more entries with the STATUS parameter set to 0 in the {{FILE|ICONST}}-file. Constraints can be used within a standard NVT or NpT MD setting introduced by {{TAG|MDALGO}}=1|2|3. Note that fixing geometric parameters related to lattice vectors is not allowed within an NVT simulation (VASP would terminate with an error message). Constraints can be combined with restraints, time-dependent bias potentials ([[:Category:Metadynamics|Metadynamics]]), monitored coordinates and other elements available within the context of MD.       
== References ==
<references>
<ref name="Ryckaert77">[http://dx.doi.org/10.1016/0021-9991(77)90098-5 J. P. Ryckaert, G. Ciccotti, and H. J. C. Berendsen, J. Comp. Phys. 23, 327 (1977).]</ref>
</references>
----
[[Category:Molecular dynamics]][[Category:Constrained molecular dynamics]][[Category:Theory]][[Category:Howto]]

Latest revision as of 06:48, 19 July 2022

Constrained molecular dynamics is performed using the SHAKE algorithm.[1]. In this algorithm, the Lagrangian for the system is extended as follows:

where the summation is over r geometric constraints, is the Lagrangian for the extended system, and λi is a Lagrange multiplier associated with a geometric constraint σi:

with ξi(q) being a geometric parameter and ξi is the value of ξi(q) fixed during the simulation.

In the SHAKE algorithm, the Lagrange multipliers λi are determined in the iterative procedure:

  1. Perform a standard MD step (leap-frog algorithm):
  2. Use the new positions q(tt) to compute Lagrange multipliers for all constraints:
  3. Update the velocities and positions by adding a contribution due to restoring forces (proportional to λk):
  4. repeat steps 2-4 until either |σi(q)| are smaller than a predefined tolerance (determined by SHAKETOL), or the number of iterations exceeds SHAKEMAXITER.

How to

Geometric constraints are introduced by defining one or more entries with the STATUS parameter set to 0 in the ICONST-file. Constraints can be used within a standard NVT or NpT MD setting introduced by MDALGO=1|2|3. Note that fixing geometric parameters related to lattice vectors is not allowed within an NVT simulation (VASP would terminate with an error message). Constraints can be combined with restraints, time-dependent bias potentials (Metadynamics), monitored coordinates and other elements available within the context of MD.


References