The Langevin thermostat[1][2][3] maintains the temperature through a modification of Newton's equations of motion

where Fi is the force acting on atom i due to the interaction potential, γi is a friction coefficient, and fi is a random force simulating the random kicks by the damping of particles between each other due to friction. The random numbers are chosen from a Gaussian distribution with the following variance

with Δt being the time-step used in the MD to integrate the equations of motion. Obviously, Langevin dynamics is identical to the classical Hamiltonian in the limit of vanishing γ.