This tutorial introduces how to calculate the ground state energy using second order Møller-Plesset perturbation theory (MP2) with VASP. Currently there are three implementations available:
This tutorial introduces how to calculate the ground state energy using second order Møller-Plesset perturbation theory (MP2) with VASP. Currently there are three implementations available:
Line 17: Line 17:
== Preparation: the Hartree-Fock ground state ==
== Preparation: the Hartree-Fock ground state ==


In order to calculate the Hartree-Fock ground state, use the following INCAR file
In order to calculate the Hartree-Fock ground state, use the following {{TAG|INCAR}} file
  {{TAGBL|ISMEAR}} = 0 ; SIGMA = 0.01
  {{TAGBL|ISMEAR}} = 0 ; {{TAGBL|SIGMA}} = 0.01
  ALGO = A
  {{TAGBL|ALGO}} = A
  LHFCALC = .TRUE. ; AEXX = 1.0
  {{TAGBL|LHFCALC}} = .TRUE. ; {{TAGBL|AEXX}} = 1.0
  EDIFF = 1E-6
  {{TAGBL|EDIFF}} = 1E-6
  ENCUT = # 10-20% larger than ENMAX in the POTCAR file
  {{TAGBL|ENCUT}} = # 10-20% larger than {{TAGBL|ENMAX}} in the {{TAGBL|POTCAR}} file
  LORBITALREAL = .TRUE. # only necessary for LTMP2 and stochastic LTMP2
  {{TAGBL|LORBITALREAL}} = .TRUE. # only necessary for LTMP2 and stochastic LTMP2
Keep the {{TAG|OUTCAR}} file to read-out the Hartree-Fock ground state energy later.
Keep the {{TAG|OUTCAR}} file to read-out the Hartree-Fock ground state energy later.


Line 33: Line 33:


Set the INCAR file to  
Set the INCAR file to  
  ISMEAR = 0 ; SIGMA = 0.01
  {{TAGBL|ISMEAR}} = 0 ; {{TAGBL|SIGMA}} = 0.01
  ALGO = Exact
  {{TAGBL|ALGO}} = Exact
  LHFCALC = .TRUE. ; AEXX = 1.0
  {{TAGBL|LHFCALC}} = .TRUE. ; {{TAGBL|AEXX}} = 1.0
  NELM = 1
  {{TAGBL|NELM}} = 1
  NBANDS = # number of plane-waves (favorably a multiple of the used mpi-ranks)
  {{TAGBL|NBANDS}} = # number of plane-waves (favorably a multiple of the used mpi-ranks)
  ENCUT = # same value as in the Hartree-Fock step
  {{TAGBL|ENCUT}} = # same value as in the Hartree-Fock step
  LORBITALREAL = .TRUE. # only necessary for LTMP2 and stochastic LTMP2
  {{TAGBL|LORBITALREAL}} = .TRUE. # only necessary for LTMP2 and stochastic LTMP2
Make sure that VASP reads the {{TAG|WAVECAR}} file from the previous Hartree-Fock step.
Make sure that VASP reads the {{TAG|WAVECAR}} file from the previous Hartree-Fock step.


Line 60: Line 60:
</references>
</references>


[[Category:Tutorials]]
----
[[Category:Many-body perturbation theory]][[Category:MP2]][[Category:Tutorials]]

Latest revision as of 10:20, 19 July 2022

This tutorial introduces how to calculate the ground state energy using second order Møller-Plesset perturbation theory (MP2) with VASP. Currently there are three implementations available:

  • MP2[1]: this implementation is recommended for very small unit cells, very few k-points and very low plane-wave cuttofs. The system size scaling of this algorithm is N⁵.
  • LTMP2[2]: for all larger systems this Laplace transformed MP2 (LTMP) implementation is recommended. Larger cutoffs and denser k-point meshes can be used. It possesses a lower system size scaling (N⁴) and a more efficient k-point sampling.
  • stochastic LTMP2[3]: even faster calculations at the price of statistical noise can be achieved with the stochastic MP2 algorithm. It is an optimal choice for very large systems where only relative errors per valence electron are relevant. Keeping the absolute error fixed, the algorithm exhibits a cubic scaling with the system size, N³, whereas for a fixed relative error, a linear scaling, N¹, can be achieved. Note that there is no k-point sampling and no spin polarization implemented for this algorithm.

NOTE: If you use one of these algorithms, please cite the corresponding reference in your publication in addition to the standard VASP reference.

Both LTMP2 as well as stochastic LTMP2 are high performance algorithms that can parallelize the MP2 calculation over thousands of CPUs.

At first, one should select the best algorithm according to the considered system size. In the following, a step by step instruction for each algorithm is presented.

Preparation: the Hartree-Fock ground state

In order to calculate the Hartree-Fock ground state, use the following INCAR file

ISMEAR = 0 ; SIGMA = 0.01
ALGO = A
LHFCALC = .TRUE. ; AEXX = 1.0
EDIFF = 1E-6
ENCUT = # 10-20% larger than ENMAX in the POTCAR file
LORBITALREAL = .TRUE. # only necessary for LTMP2 and stochastic LTMP2

Keep the OUTCAR file to read-out the Hartree-Fock ground state energy later.

Calculating the unoccupied Hartree-Fock orbitals

We also need the unoccupied/virtual Hartree-Fock orbitals to perform MP2 calculations. The number of necessary orbitals should be equal to the number of plane-waves, that can be found via

nplw=`awk '/number of plane-waves:/ {print $5} ' < OUTCAR_HARTREE_FOCK_GROUND_STATE

For the Gamma-only version of VASP, twice the number of plane-waves have to be used.

Set the INCAR file to

ISMEAR = 0 ; SIGMA = 0.01
ALGO = Exact
LHFCALC = .TRUE. ; AEXX = 1.0
NELM = 1
NBANDS = # number of plane-waves (favorably a multiple of the used mpi-ranks)
ENCUT = # same value as in the Hartree-Fock step
LORBITALREAL = .TRUE. # only necessary for LTMP2 and stochastic LTMP2

Make sure that VASP reads the WAVECAR file from the previous Hartree-Fock step.

Actual MP2 calculations

Depending on your choice, please switch to the corresponding page.

References