LOCPOT: Difference between revisions

From VASP Wiki
No edit summary
No edit summary
 
(12 intermediate revisions by 5 users not shown)
Line 1: Line 1:
The {{TAG|LOCPOT}} file contains the total local potential (in eV).
The {{FILE|LOCPOT}} file stores the local potential (in eV). The definition of the written local potential depends on the settings for {{TAG|LVTOT}}, {{TAG|LVHAR}}, and {{TAG|WRT_POTENTIAL}}.


Available up from VASP version 2.0.
The format is similar to that of the {{TAG|CHGCAR}} file, but it does not have the same data arrangement.
For spin-unpolarized calculations ({{TAG|ISPIN}}=1, {{TAG|LNONCOLLINEAR}}=F), it contains a single dataset with the scalar potential.
For spin-polarized calculations ({{TAG|ISPIN}}=2), it contains two datasets: spin up and spin down.
For noncollinear calculations ({{TAG|LNONCOLLINEAR}}=T), it contains four datasets in the spinor representation of the potential. In other words, it contains the scalar potential and the B-field-like potential <math>B_1</math>, <math>B_2</math>, and <math>B_3</math> in the basis defined by {{TAG|SAXIS}} (see [[Known_issues#ncl-LOCPOT|LOCPOT-format issue for VASP<6.4.3]]).
{{NB|warning|Note for versions older than vasp.5.1.12: please check whether your version supports this tag (it is written out at the beginning of the OUTCAR file). Versions not supporting {{TAG|LVHAR}} might or not add <math>V_{\text{XC}}(\mathbf{r})</math>. Please check this by searching for <tt>LEXCHG{{=}}-1</tt> in <tt>main.F</tt>. If the line <tt>LEXCHG{{=}}-1</tt> is commented out <math>V_{\text{XC}}(\mathbf{r})</math> is added otherwise it is not.}}


To write this file, the line
== Related tags and articles ==
{{TAG|LVACPOTAV}},
{{TAG|LVTOT}},
{{TAG|LVHAR}},
{{TAG|WRT_POTENTIAL}},
{{FILE|POT}}


LVTOT = .TRUE.


must exist in the {{TAG|INCAR}} file. In the present version, the only electrostatic part of the potential is written (exchange correlation is not added). This is desirable for the evaluation of the work-function, because the electrostatic potential converges more rapidly to the vacuum level than the total potential. However if the exchange correlation potential is to be included, change one line in main.F:
[[Category:Files]][[Category:Output Files]][[Category:Electrostatics]]
! comment out the following line to add  exchange correlation
!        INFO%LEXCHG=-1
          CALL POTLOK(...)
 
Mind:
Older versions might have had a different behavior, when they were retrieved from the server. Please always check yourself, whether main.F is working in the way you expect (simply search for ''LEXCHG=-1'' in main.F). If the line ''LEXCHG=-1'' is commented out, the exchange correlation is added. It is recommended to avoid wrap around errors, when evaluating {{TAG|LOCPOT}}. This can be done by specifying {{TAG|PREC}}=''High'' in the {{TAG|INCAR}} file.
The data arrangement on the {{TAG|LOCPOT}} file is similar to that of the {{TAG|CHGCAR}} file.
 
----
 
[[The_VASP_Manual|Contents]]
 
[[Category:Files]]

Latest revision as of 07:12, 7 February 2024

The LOCPOT file stores the local potential (in eV). The definition of the written local potential depends on the settings for LVTOT, LVHAR, and WRT_POTENTIAL.

The format is similar to that of the CHGCAR file, but it does not have the same data arrangement. For spin-unpolarized calculations (ISPIN=1, LNONCOLLINEAR=F), it contains a single dataset with the scalar potential. For spin-polarized calculations (ISPIN=2), it contains two datasets: spin up and spin down. For noncollinear calculations (LNONCOLLINEAR=T), it contains four datasets in the spinor representation of the potential. In other words, it contains the scalar potential and the B-field-like potential , , and in the basis defined by SAXIS (see LOCPOT-format issue for VASP<6.4.3).

Warning: Note for versions older than vasp.5.1.12: please check whether your version supports this tag (it is written out at the beginning of the OUTCAR file). Versions not supporting LVHAR might or not add . Please check this by searching for LEXCHG=-1 in main.F. If the line LEXCHG=-1 is commented out is added otherwise it is not.

Related tags and articles

LVACPOTAV, LVTOT, LVHAR, WRT_POTENTIAL, POT