Molecular dynamics calculations: Difference between revisions

From VASP Wiki
Line 7: Line 7:
== Main INCAR tags ==
== Main INCAR tags ==
*{{TAG|IBRION}}=0: Molecular dynamics calculations are enabled by setting the {{TAG|IBRION}} tag to 0.
*{{TAG|IBRION}}=0: Molecular dynamics calculations are enabled by setting the {{TAG|IBRION}} tag to 0.
*{{TAG|MDALGO}}: This tag selects the type of molecular dynamics calculations that is going to be executed (regular equations of motion, metadynamics etc.). It also includes the choice of ensemble, thermostat and barostat.  
*{{TAG|MDALGO}}: This tag selects the type of thermostat used in the molecular dynamics calculations. For regular molecular dynamics calculations the thermostat is selected by a one digit number (e.g. 1 for Andersen, 2 for Nose-Hoover etc.). For biased molecular dynamics, metadynamics etc. the thermostat is selected by a two digit number where the first digit corresponds to the thermostat analogously to regular molecular dynamics and the second digit corresponds to the molecular dynamics type (e.g. 11 metadynamics with Andersen thermostat, 21 metadynamics with Nose-Hoover thermostat etc.).
 
*{{TAG|ISIF}: This tag controls which type of ensemble is chosen (NVT or NPT).


== Combination of Ensembles and thermostats ==
== Combination of Ensembles and thermostats ==

Revision as of 10:43, 29 May 2019

Compilation

First of all to run molecular dynamics calculation VASP has to be compiled using the -Dtbdyn precompiler flag in the makefile.include file. A sample input using this tag would look like this:

CPP     = $(CPP_) -DHOST=\"IFC9_fftw\" \
          -Dkind8 -DNGXhalf  -DCACHE_SIZE=12000 -DPGF90 -Davoidalloc  \
          -Dtbdyn

Main INCAR tags

  • IBRION=0: Molecular dynamics calculations are enabled by setting the IBRION tag to 0.
  • MDALGO: This tag selects the type of thermostat used in the molecular dynamics calculations. For regular molecular dynamics calculations the thermostat is selected by a one digit number (e.g. 1 for Andersen, 2 for Nose-Hoover etc.). For biased molecular dynamics, metadynamics etc. the thermostat is selected by a two digit number where the first digit corresponds to the thermostat analogously to regular molecular dynamics and the second digit corresponds to the molecular dynamics type (e.g. 11 metadynamics with Andersen thermostat, 21 metadynamics with Nose-Hoover thermostat etc.).
  • {{TAG|ISIF}: This tag controls which type of ensemble is chosen (NVT or NPT).

Combination of Ensembles and thermostats

Thermostat
Ensemble Andersen Nose-Hoover Langevin Multiple Andersen
Microcanonical (NVE) MDALGO=1, ANDERSEN_PROB=0.0
Canonical (NVT) MDALGO=1 MDALGO=2 MDALGO=3 MDALGO=13
ISIF=2 ISIF=2 ISIF=2 ISIF=2
Isobaric-isothermal (NpT) not available not available MDALGO=3 not available
ISIF=3
Isoenthalpic-isobaric (NpH) MDALGO=3, ISIF=3, LANGEVIN_GAMMA=LANGEVIN_GAMMA_L=0.0